CX335 Technical Manual Page 13
5.08 Gain Reduction Meter:
A nine segment LED bargraph meter continuously monitors the gain reduction applied by
the compressor and or limiter and even any remote control voltage over the range 0 to
30dB. The amount of gain reduction shown is greatly affected by all of the front panel
controls. Due to the transparent action of the compressor, more activity will probably be
shown than is audibly evident. It is anticipated that the 30dB LED will seldom illuminate
even in abuse conditions.
5.09 Output Level Meters:
These are nine segment LED bargraph level meters that monitor the level of the two
output signals over the range -20dB to +12dB with reference to the 0dBu operating level.
With average stereo programme these will track together. Vastly differing levels will most
likely be a cable short or external system configuration fault.
30 20 15 10 6 4 2 1
OUTPUT DISPLAY
-20 -16 -12 -8 -4 0dB +4 +8 +12
0dB
L
R
GAIN REDUCTION