CXM Technical
MANUAL
15
4.18 Sound to Light Output
This fully floating, transformer coupled output facility can be used to trigger sound to light
controllers. The signal is derived from the main output and is rated at +10dBu (2.45V)
with a minimum load of 600Ω. Connection is by way of a 2 pole 1/4" jack socket.