2.08 Stereo/mono
A mono switch is included and this simply links the two stereo signals, the
adjacent LED illuminates when the signals are linked.
2.09 Crossfade Assignment
Two crossfade assign switches are provided; with both switch A and switch B in
the off position, stereo signals are routed to bypass the crossfade circuitry.
Switch A routes signals to channel A and similarly switch B to channel B;
adjacent LED's indicate the selected channel. The switches are arranged to give
priority to channel A necessitating the release of channel A prior to selecting
channel B. (See 4.01 and 4.02 for details of crossfade and chopfade on master
module).
2.10 Auxiliary Sends
Two auxiliary sends are provided and can be individually configured to operate
in the pre-fade or post-fade mode by simply reversing a single circuit jumper
(see detail). This facility can be used to interface a variety of units for signal
processing, sampling, digital effects or as a flexible extra output facility. Factory
settings configure Aux 1 pre-fade and Aux 2 post-fade.
2.11 Balance Control
The balance control operates at -3dB at centre to infinity at extremes, with a
centre detent to aid positive positioning.
2.12 PFL (Pre Fade Listen)
This logic controlled momentary action switch routes the pre-fade signals to the
headphone amplifier and lower stereo LED bargraph display. The selection of a
channel PFL automatically cancels any prior selection. The adjacent LED
indicates status.
2.13 Peak LED
A red LED indicates the peak signal level at the pre-fade point and illuminates at
a level of approximately 4dB below clipping.
2.14 Channel Fader
The channel fader has a slide length of 100mm and an exceptionally smooth
feel. Under normal operating conditions, the fader is used fully open or fully off.
2.15 Remote start switch
A low voltage, fully floating, momentary action switch is fitted as standard. The
contact rating is 30V at 0.1A and is terminated with a 2 pole 3.5mm jack socket.